AC Current Transducers and Switches, cs-, sc-, xd

For full specification Click Here
 Features

 CT Style Current Transducers & Switches
 Easy and Economical to use
 Moulded Case Insulation to 600VAC
 Standard Ring Type or Split Core Versions
 0-5VDC & 0-10VDC Output Versions
 Loop Powered 4-20mA Output Version
 Solid State Relay Output Versions
 Most Versions Selectable Input Ranges
 High Accuracy
AC Current Transducers & Switches
Signal Control Relays and Trip Amplifiers, Signal Control Relays & Trip Amplifiers, YWRU, YWRIT, 2002, 4002, 2002-ALM, 4002-ALM,2002 ALM, 4002 ALM

For full specification Click Here
 2002-ALM
 Dual trip amplifier, 12VDC to 24VAC supply voltages

 4002-ALM
 Dual trip amplifier, 24VDC to 240VAC supply voltages
Dual trip amplifier
CEWE INSTRUMENT, Electrical Transducers - CEWE INSTRUMENTS, DI11, DI01, DI02, DU11, DU01, DU02, DU61, DU62,

For full specification Click Here
In this section the wide range of CEWE INSTRUMENT BLUE MODULE Transducers is described - these are suitable for DIN-rail mounting.
Owing to their excellent performance and high reliability (e.g. a MTBF of 40 years for current transducers) CEWE INSTRUMENT transducers are now used by power utilities and industry in over 20 European countries as well as in other parts of the world.
The output from our transducers are, within certain limits, independent of load. The load limits are given on the data sheets. The load impendence is obtained by feedback of the output signal to the input of the amplifier.
These transducer characteristics give great advantages among which the most important are:-
 Measuring unit can be measured over relatively long distances.
 Within the framework of permitted output signal loadings, several measuring or registration units can be connected simultaneously to the same transducer. No special tuning is required.
 They have a wide range of applications because of there high accuracy and the fact that they are approved in accordance with interference tests IEC 255 -5 and -6, both for input and output signals.
Electrical Transducers - CEWE INSTRUMENTS
Signal Isolators and Converters, bob

For full specification Click Here
A din rail mounted four way AC current transducer. Accepting up to four inputs from the miniature split core current transformers supplied as a "kit" with the unit and giving four isolated analogue voltage signal outputs, either 0-5V DC or 0-10V DC. The maximum primary current possible is 50Amps which is compatible with the 10mm ID of the split core CT. The YW4 has individual pairs of terminals for the CT inputs, whilst the output channels share a common 0V rail. The YW4 requires a separate AC or DC supply voltage with isolation offered via an internal transformer or DC to DC converter.
FOUR WAY AC CURRENT TRANSDUCER 4 x 0.1-50 AMPS INPUTS yw4
Frequency to Analogue Converter, pxf, freqcon,

For full specification Click Here
PXF-20
A din rail mounted pulse frequency to analogue signal converter and isolator, only 22.5mm wide. Input frequency range selection is via a rotary switch on the front panel. Input source can be from either NPN, PNP or NAMUR selectable by the connecting to various input terminals. Output selection is also via a choice of wiring options on the output terminals. The front panel is also fitted with dual LED indication to give at a glance status, plus adjustable zero and span potentiometers.

Freqcon
The FREQCON is a frequency to analogue converter which can be programmed using a PC to perform any frequency to analogue converting function. The range of frequency input available is 0 - 1MHz and any offset can be introduced on the input . In addition a 21 point look-up table can be used to linearise non-linear inputs, with other linearisation functions such as square-root and custom polynomial also being available.The operational status of the unit is indicated by the front panel LED, a slow flashing indicating normal operation, a fast flash indicating an input failure, or hard off indicating a power supply failure. The unit can only be powered by any D.C. supply from 16 to 32 volts.
Frequency to Analogue Converter
Lightning Current & Voltage Surge Arresters, Protec, Probloc,

For full specification Click Here
■ Modular Din Rail construction
■ Voltage surge arresters class II
■ Combined Lightning & Voltage Surge arresters class I & II
■ Protection levels up to 25KA per pole 10/350
■ Suitable for both AC & DC systems
Lightning Current & Voltage Surge Arresters
Loop powered Isolator and Isolating terminal blocks, Loop Powered Isolator & Isolating Terminal Blocks, 420i, 420tw

For full specification Click Here
420i
The 420i loop powered isolator is a 0(4)-20mA direct current isolator. The isolator derives its power from the input signal and therefore requires no external power supply.

Two other variants are also available. The 420i-1 which has a built in precision 250Ù resistor to give a 1-5V output, and the 420V which gives a 0-10V output from a 4-20mA input, whilst dropping just 5V from the input loop.

420-TW
The 420-TW series of isolating terminal blocks can replace standard DIN-rail terminals to provide input isolation, signal conversion and excellent RFI and noise rejection. Input available include thermocouple, RTD, current and voltage and the standard output is 4-20mA. For thermocouple inputs, internal rotary switches allow the user to select virtually any type of thermocouple and the temperature range required.
Loop Powered Isolator & Isolating Terminal Blocks
NMC Transducers

For full specification Click Here
Look at this for a great idea, do you ultimately need an analogue signal for your current measurement ? Many of the CTs feature a plug in transducer module option.

Just twist of the secondary terminal covers and remove the secondary terminal screws. Screw in the brass transformer to module connecting studs and plug in the NMC module.

Each NMC transducer block will give two different isolated analogue outputs. Also the secondary of the current transformer is repeated, if this repeat facility is not required the supplied shorting link must be left in situ. It is possible to generate 0-20mA and 0-10VDC without any auxiliary supply (self powered module version). Please note that the self powered versions can only be used on current transformers with an output of at least 2.5VA, if a 4-20mA signal is required in all cases an auxiliary supply is required, 24VDC, 110VAC or 230VAC.
NMC Transducers
PT100 Temperature to Analogue Converter

For full specification Click Here
 Slim Modern Design
 Input Range Selectable
 2 or 3 Wire Selectable
 Analogue output signal selectable
 LED Indication
 3.75KV Isolation
 Zero & Span Adjustment

A DIN rail mounted PT100 temperature to analogue signal converter and isolator, only 22.5mm wide. Input range and 2 or 3 wire selection is via connecting to various input terminals. Output selection is also via a choice of wiring options on the output terminals. The front panel is also fitted with dual LED indication to give at a glance status, plus adjustable zero and span potentiometers.
PT100 Temperature to Analogue Converter
Signal Isolators and Converters, PXU-20. Isocon, Dualcon, SC-VA,

For full specification Click Here
PXU-20 - Input & Output Selectable Analogue Signal Isolator & Converter
 Slim Modern Design  Input & Output Selectable  LED Indication  3.75KV Isolation  Zero & Span Adjustment

ISOCON - Isolating Signal Converters
 Only 12.5mm Wide  Full 3-Port Isolation  Zero & Span Adjustment  High Accuracy
 Wide Range of Inputs Available  AC & DC Power Supply Options

DUALCON - Isolating Signal Converters - 1 Input, 2 Outputs
 Only 17.5mm Wide  Full 4-Port Isolation  Zero & Span Adjustment  Two Isolated Outputs from One Input
 Wide Range of Inputs Available  AC & DC Power Supply Options

SC-VI-1 & SC-VI-2 - Isolating Signal Converters - 1 output & 2 outputs
 22.5mm Wide  2KV Isolation  Zero & Span Adjustment  2x Selectable Outputs  5x Selectable Inputs  AC & DC Aux
Signal Isolator & Signal Converters