FOOT MOUNTED OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 130mm
MAX CONDUCTOR SIZE 70mm DIA
MAX BUS-BAR SIZE 100 x 10mm OR 2 x 80 x 10mm
PRIMARY RANGES FROM 500AMPS TO 2500AMPS
1AMP OR 5AMP SECONDARIES
ASK101.4
For full specification Click Here
ASK103.3 Features
FOOT MOUNTED OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 172mm
MAX CONDUCTOR SIZE 85mm DIA
MAX BUS-BAR SIZE 2 x 100 x 10mm OR 3 x 80 x 10mm
PRIMARY RANGES FROM 800AMPS TO 3000AMPS
1AMP OR 5AMP SECONDARIES
ASK103.3
For full specification Click Here
ASK103.41 Features
FOOT MOUNTED OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 199mm
MAX BUS-BAR SIZE 103 x 41mm
PRIMARY RANGES FROM 400AMPS TO 2000AMPS
1AMP OR 5AMP SECONDARIES
ASK103.41
For full specification Click Here
ASK105.6 Features
FOOT OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 129mm
MAX BUS-BAR SIZE 100 x 55mm
PRIMARY RANGES FROM 600AMPS TO 2000AMPS
1AMP OR 5AMP SECONDARIES
ASK105.6
For full specification Click Here
ASK105.6N Features
FOOT OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 129mm
MAX BUS-BAR SIZE 100 x 55mm
PRIMARY RANGES FROM 2500AMPS TO 5000AMPS
1AMP OR 5AMP SECONDARIES
ASK105.6N
For full specification Click Here
ASK123.3 Features
FOOT MOUNTED OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 172mm
MAX CONDUCTOR SIZE 100mm DIA
MAX BUS-BAR SIZE 123 x 30mm OR 3 x 100 x 10mm
PRIMARY RANGES FROM 1000AMPS TO 4000AMPS
1AMP OR 5AMP SECONDARIES
ASK123.3
For full specification Click Here
ASK127.4 Features
FOOT OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 159mm
MAX BUS-BAR SIZE 120 x 70mm
PRIMARY RANGES FROM 1000AMPS TO 2500AMPS
1AMP OR 5AMP SECONDARIES
ASK127.4
For full specification Click Here
ASK128.4 Features
FOOT MOUNTED OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 100mm
MAX BUS-BAR SIZE 128 x 38mm
PRIMARY RANGES FROM 400AMPS TO 4000AMPS
1AMP OR 5AMP SECONDARIES
ASK128.4
For full specification Click Here
ASK129.10 Features
FOOT OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 250mm
MAX BUS-BAR SIZE 120 x 90mm
PRIMARY RANGES FROM 1000AMPS TO 7500AMPS
1AMP OR 5AMP SECONDARIES
ASK129.10
For full specification Click Here
ASK130.5 Features
FOOT OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 180mm
MAX BUS-BAR SIZE 130 x 30mm
PRIMARY RANGES FROM 300AMPS TO 3200AMPS
1AMP OR 5AMP SECONDARIES
ASK130.5
For full specification Click Here
ASK231.5 Features
FOOT OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 49.5mm
MAX CONDUCTOR SIZE 28mm DIA.
MAX BUS-BAR SIZE 30 x 10mm
PRIMARY RANGES FROM 50AMPS TO 600AMPS
1AMP OR 5AMP SECONDARIES
ASK231.5
For full specification Click Here
ASK31.3 Features
DIN RAIL, BUS-BAR OR FOOT MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 60mm
MAX CONDUCTOR SIZE 26mm DIA
MAX BUS-BAR SIZE 30 x 10mm
PRIMARY RANGES FROM 50AMPS TO 750AMPS
1AMP OR 5AMP SECONDARIES
ASK31.3
For full specification Click Here
ASK31.5 Features
DIN RAIL, BUS-BAR OR FOOT MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 60mm
MAX CONDUCTOR SIZE 28mm DIA.
MAX BUS-BAR SIZE 2 X 20 X 10mm OR 30 X 10mm
PRIMARY RANGES FROM 40AMPS TO 600AMPS
1AMP OR 5AMP SECONDARIES
ASK31.5
For full specification Click Here
ASK318.3 Features
DIN RAIL, BUS-BAR OR FOOT MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 60mm
MAX CONDUCTOR SIZE 26mm DIA
MAX BUS-BAR SIZE 31 x 18mm
PRIMARY RANGES FROM 60AMPS TO 750AMPS
1AMP OR 5AMP SECONDARIES
ASK318.3
For full specification Click Here
ASK41.3 Features
DIN RAIL, BUS-BAR OR FOOT MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 60mm
MAX CONDUCTOR SIZE 26mm DIA
MAX BUS-BAR SIZE 40 x 12mm OR 32 x 18mm
PRIMARY RANGES FROM 100AMPS TO 800AMPS
1AMP OR 5AMP SECONDARIES
ASK41.3
For full specification Click Here
ASK41.4 Features
DIN RAIL, BUS-BAR OR FOOT MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 70mm
MAX CONDUCTOR SIZE 32mm DIA
MAX BUS-BAR SIZE 40 x 10mm OR 2 x 30 x 5mm
PRIMARY RANGES FROM 50AMPS TO 1000AMPS
1AMP OR 5AMP SECONDARIES
ASK41.4
For full specification Click Here
ASK412.4 Features
DIN RAIL, BUS-BAR OR FOOT MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 70mm
MAX CONDUCTOR SIZE 30.5mm DIA
MAX BUS-BAR SIZE 40 x 12mm OR 30 x 15mm
PRIMARY RANGES FROM 50AMPS TO 800AMPS
1AMP OR 5AMP SECONDARIES
ASK412.4
For full specification Click Here
ASK51.4 Features
FOOT MOUNTED OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 85mm
MAX CONDUCTOR SIZE 44mm DIA
MAX BUS-BAR SIZE 2 X 40 X 10 mm OR 50 X 12mm
PRIMARY RANGES FROM 100AMPS TO 1200AMPS
1AMP OR 5AMP SECONDARIES
ASK51.4
For full specification Click Here
ASK541.4 Features
FOOT MOUNTED OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 85mm
MAX CONDUCTOR SIZE 32mm DIA
MAX BUS-BAR SIZE 2 x 30x 5mm OR 40 x 10mm
PRIMARY RANGES FROM 30AMPS TO 1000AMPS
1AMP OR 5AMP SECONDARIES
ASK541.4
For full specification Click Here
ASK561.4 Features
FOOT OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 85mm
MAX CONDUCTOR SIZE 44mm DIA
MAX BUS-BAR SIZE 60 x 10mm OR 2 x 50 x 10mm
PRIMARY RANGES FROM 200AMPS TO 1200AMPS
1AMP OR 5AMP SECONDARIES
ASK561.4
For full specification Click Here
ASK61.4 Features
FOOT OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 95mm
MAX CONDUCTOR SIZE 44mm DIA
MAX BUS-BAR SIZE 63 x 10mm OR 2 x 50 x 10mm
PRIMARY RANGES FROM 200AMPS TO 1600AMPS
1AMP OR 5AMP SECONDARIES
ASK61.4
For full specification Click Here
ASK63.4 Features
FOOT OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 95mm
MAX CONDUCTOR SIZE 44mm DIA
MAX BUS-BAR SIZE 60 x 30mm OR 50 x 40mm
PRIMARY RANGES FROM 300AMPS TO 2000AMPS
1AMP OR 5AMP SECONDARIES
ASK63.4
For full specification Click Here
ASK63.6 Features
FOOT OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 88mm
MAX CONDUCTOR SIZE 30mm DIA
MAX BUS-BAR SIZE 60 x 30mm
PRIMARY RANGES FROM 200AMPS TO 2000AMPS
1AMP OR 5AMP SECONDARIES
ASK63.6
For full specification Click Here
ASK81.4 Features
FOOT OR BUS-BAR MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
TRANSFORMER WIDTH 120mm
MAX CONDUCTOR SIZE 55mm DIA
MAX BUS-BAR SIZE 80 x 10mm OR 60 x 30 OR 2 x 60 x 10mm
PRIMARY RANGES FROM 400AMPS TO 2000AMPS
1AMP OR 5AMP SECONDARIES
ASK81.4
For full specification Click Here
ASK83.4 Features
FOOT MOUNTED OR BUS-BAR MOUNTED
DUAL POSITION OF SECONDARY TERMINALS (TOP & SIDE)
INSULATED ENDS TO BUS-BAR PINCH SCREWS
EXTERNAL DIMENSION 116 x 96mm
MAX BUS-BAR SIZE 84 X 34mm
PRIMARY RANGES FROM 300AMPS TO 2500AMPS
1AMP OR 5AMP SECONDARIES
ASK83.4
For full specification Click Here
ASR20.3 Features
DIN RAIL MOUNTED OR FOOT MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
TRANSFORMER WIDTH 44mm
MAX CONDUCTOR SIZE 21mm DIA
PRIMARY RANGES FROM 50AMPS TO 300AMPS
1AMP OR 5AMP SECONDARIES
ASR20.3
For full specification Click Here
ASR21.3 Features
DIN RAIL MOUNTED OR FOOT MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
TRANSFORMER WIDTH 48.5mm
MAX CONDUCTOR SIZE 22.5mm DIA
PRIMARY RANGES FROM 100AMPS TO 600AMPS
1AMP OR 5AMP SECONDARIES
ASR21.3
For full specification Click Here
ASR22.3 Features
DIN RAIL MOUNTED OR FOOT MOUNTED
SNAP FIT SECONDARY TERMINAL COVERS
TRANSFORMER WIDTH 60mm
MAX CONDUCTOR SIZE 22.5mm DIA
PRIMARY RANGES FROM 40AMPS TO 600AMPS
1AMP OR 5AMP SECONDARIES
ASR22.3
For full specification Click Here
KBU23 Features
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
UNIQUE SNAP SHUT & RELEASE ACTION
TRANSFORMER WIDTH 93mm
MAX BUS-BAR SIZE 20 x 30mm
PRIMARY RANGES FROM 100AMPS TO 400AMPS
1AMP OR 5AMP SECONDARIES
KBU23
For full specification Click Here
KBU58 Features
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
UNIQUE SNAP SHUT & RELEASE ACTION
TRANSFORMER WIDTH 125mm
MAX BUS-BAR SIZE 50 x 80mm
PRIMARY RANGES FROM 250AMPS TO 1000AMPS
1AMP OR 5AMP SECONDARIES
KBU58
For full specification Click Here
KBU812 Features
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
UNIQUE SNAP SHUT & RELEASE ACTION
TRANSFORMER WIDTH 155mm
MAX BUS-BAR SIZE 80 x 120mm
PRIMARY RANGES FROM 250AMPS TO 1500AMPS
1AMP OR 5AMP SECONDARIES
KBU812
For full specification Click Here
KBU816 Features
SNAP FIT SECONDARY TERMINAL COVERS
INSULATED ENDS TO BUS-BAR PINCH SCREWS
UNIQUE SNAP SHUT & RELEASE ACTION
TRANSFORMER WIDTH 193mm
MAX BUS-BAR SIZE 80 x 160mm
PRIMARY RANGES FROM 1000AMPS TO 5000AMPS
1AMP OR 5AMP SECONDARIES
KBU816
For full specification Click Here
Look at this for a great idea, do you ultimately need an analogue signal for your current measurement ? Many of the CTs feature a plug in transducer module option.
Just twist of the secondary terminal covers and remove the secondary terminal screws. Screw in the brass transformer to module connecting studs and plug in the NMC module.
Each NMC transducer block will give two different isolated analogue outputs. Also the secondary of the current transformer is repeated, if this repeat facility is not required the supplied shorting link must be left in situ. It is possible to generate 0-20mA and 0-10VDC without any auxiliary supply (self powered module version). Please note that the self powered versions can only be used on current transformers with an output of at least 2.5VA, if a 4-20mA signal is required in all cases an auxiliary supply is required, 24VDC, 110VAC or 230VAC.
NMC Transducer
For full specification Click Here
Look at this for a great idea, do you ultimately need a relay contact output for your current measurement? Many of the CTs feature a plug in relay module option.
Just twist of the secondary terminal covers and remove the secondary terminal screws. Screw in the brass transformer to module connecting studs and plug in the OCR module.
The OCR modules provide two volt free contact outputs rated at 5Amps 1N/C and 1N/O, connected to an adjustable time delay to avoid nuisance tripping. The OCR modules always require an auxiliary supply, 24VAC is also possible with the OCR module.
OCR Current Relay
For full specification Click Here
Summation current transformers enable the summation of several independant loads on different supplies.
An example three 3 phase supplies to be read by one KWh meter.
Supply 1: 200Amps, Supply 2: 800Amps, supply 3: 1000Amps
Required for each supply are three main CTs of the above primary currents, one for each phase R/Y/B. Also required will be three, 3 input summation CTs, each of the summation CTs must be designated to a phase. The secondaries from the Red phase main CTs should be fed to the inputs of the Red phase summation CT, likewise the same applies for Yellow and Blue phases. The secondary output from the summation CT will then equal the sum of the 3 primary currents:- 200/5 + 800/5 + 1000/5 = 2000/5. The meter being used must therefore be calibrated for 2000/5.
The above example of summation CTs have unbalanced ratio inputs and therefore have to be manufactured to order. Balanced ratio input summation CTs are usually ex-stock.
Summation CTs can also be used for subtraction purposes by reversing the polariry of the inputs. It is also possible to summate a mixture of single phase and three phase supplies.
Summation CTs
For full specification Click Here
WSK40 Features
DIN RAIL MOUNTED OR FOOT MOUNTED
SNAP FIT TERMINAL COVERS
TRANSFORMER WIDTH 70mm
PRIMARY RANGES FROM 1AMP TO 40AMPS
1AMP OR 5AMP SECONDARIES