5 digit microprocessor meter with relay outputs, analogue signal output, RS485
Din 96x48mm 5 digit digital panel meters, available with a wide choice of both DC and AC inputs, along with many process inputs. The meter can be specified with a choice of one of three outputs, one relay (non adjustable from the front) can be specified as latched or non latched, an isolated analogue output or RS485 MODBUS RTU. The meter utilises the latest microprocessor technology in both the setting and operation of the meter.
CS1
For full specification Click Here
DC Ampere hour meter with relay outputs, analogue output, RS485
A Din 96x48mm DC Ampere Hour meter, taking a current reference from a DC shunt and integrating this reference against time to achieve an Ampere Hour or Ampere Minute reading. There are two display screens, the main ten digit screen is the totaliser display, the other screen is a "Batch" programmable setting. The meter can be specified with up to four relay outputs (2C/O and 2N/O) which can be assigned at the time of ordering for many functions to control say an electroplating system. As an option RS485 MODBUS is also available. Three volt free control inputs are featured as standard for functions such as reset.
CS2-TM
For full specification Click Here
Din 48x24 digital microprocessor meter with relay outputs, analogue signal output, RS485
Miniature Din 48x24mm 5 digit panel meters, available with a wide choice of DC analogue voltage and current signal inputs, along with potentiometer and resistance inputs. These meters can be specified with one or two relay outputs, plus if required an analogue output or RS485 MODBUS RTU. An excitation supply of 24VDC max 30mA is featured as standard on the CS3-PR version. These meters utilise the latest microprocessor technology in both the setting and operation of the meter.
CS3
For full specification Click Here
3½ Digit panel meter
Measuring DCA, DCV, ACA, ACV, Hz
Accuracy DC: ±0.1%, AC: ±0.2%
3½ Digital display : 1999
Peak Hold function (option)
Easy to wire, screw type terminal
DIN standard 96x48mm
High stability & low cost
CSM-321
For full specification Click Here
4½ Digit panel meter
Measuring DCA, DCV, ACA, ACV, Hz
Accuracy DC: ±0.04%, AC: ±0.1%
4½ Digital display: 19999
Easy to wire, screw type terminal
1/8 DIN standard (96x48mm)
High stability & low cost
CSM-421
For full specification Click Here
Din 48x24mm 3½ digit panel meter
Measuring DCA, DCV, ACA, ACV, Temperature
Accuracy ±0.1% DC: ±0.25% AC
0.2% (Pt100): ±1% (K, J Thermocouple)
3½ Digital display : 1999
1/32 DIN (48 x 24mm)
High stability & low cost
CSMS-321
For full specification Click Here
3½ Digit process meter
Measuring Process Signals; mA, Vdc,
Potentiometer, Pulse/u.
Accuracy ±0.1%
3½ Digital display : 1999
Easy to wire, screw type terminal
1/8 DIN standard (96 x 48mm)
High stability & low cost
CSR-321
For full specification Click Here
4½ Digit process meter
Measuring Process Signals mA, Vdc,
Potentiometer, Pulse/u.
Accuracy ±0.04%
4½ Digital display: 19999
Easy to wire, screw type terminal
1/8 DIN standard (96 x 48mm)
High stability & low cost
CSR-421
For full specification Click Here
Relay output trip meters 4 digit type (9999)
A Din 96x48mm digital panel meter available in a 4 digit option with either one or two relay setpoint outputs. If one output is ordered this can be designated as a Low or High output in the ordering and in the case of two relay outputs Low/Low, High/High, High/Low. Also an extra output is provided as a Go output. This meter combines the traditional but popular user friendly front panel thumbwheel type push button switches to set the setpoints with the latest microprocessor technology.
CSS-40
For full specification Click Here
Relay output trip meter 4½ digit type (19999)
A Din 96x48mm digital panel meter available in a 4½ digit option with either one or two relay setpoint outputs. If one output is ordered this can be designated as a Low or High output in the ordering and in the case of two relay outputs Low/Low, High/High, High/Low. Also an extra output is provided as a Go output. This meter combines the traditional but popular user friendly front panel thumbwheel type push button switches to set the setpoints with the latest microprocessor technology.
CSS-41
For full specification Click Here
Relay output trip meters 5 digit type (99999)
A Din 96x48mm digital panel meter available in a 5 digit option with either one or two relay setpoint outputs. If one output is ordered this can be designated as a Low or High output in the ordering and in the case of two relay outputs Low/Low, High/High, High/Low. Also an extra output is provided as a Go output. This meter combines the traditional but popular user friendly front panel thumbwheel type push button switches to set the setpoints with the latest microprocessor technology.
CSS-50
For full specification Click Here
3½ Digit temperature meter
Measuring T/C: K,J,T,E,R RTD: PT100
Accuracy ±0.2% (T/C) ±0.1% (PT100)
3½ Digital display : 1999
Easy to wire, screw type terminal
DIN standard (96x48mm)
High stability & low cost
CST-321
For full specification Click Here
3½ Digit six channel temperature meter
Measuring T/C: K,J,T,E,R RTD: PT100
Accuracy T/C:±0.25%, RTD:±0.1%
3½ Digit display : 1999
Easy to wire, screw type terminal
DIN standard (96x48mm)
High stability & low cost
CST-321M
For full specification Click Here
TYPE A
Primary current 10 Amps to 200 Amps
TYPE B
Primary current 200 Amps to 600 Amps
TYPE C
Primary current 800 Amps to 2000 Amps
TYPE D
Primary current 3000 Amps to 5000 Amps
ALL TYPES
Standard accuracy ±-1% (0.5% & 0.25% on request)
Specify with model the secondary: 50mV, 60mV 75mV, 100mV
DC Shunts
For full specification Click Here
4½ Digit power meter with relay outputs, analogue signal output, RS485
Din 96x48mm digital single parameter power meters either as Watts, VAR or Power Factor. The meters can be specified for both single and three phase systems, 3 or 4 wire and are suitable for both balanced and unbalanced loads. The meters can be specified as a "display only" meter, or with a choice of one or two outputs. One relay or two relays that can be specified as latched or non latched, or an isolated analogue output with or without one relay output. Or with, or without RS485 MODBUS RTU which can also be with or without one relay output. The meter utilises the latest microprocessor technology in both the setting and operation of the meter.
MPF-5 (COS)
For full specification Click Here
4½ Digit power meter with relay outputs, analogue signal output, RS485
Din 96x48mm digital single parameter power meters either as Watts, VAR or Power Factor. The meters can be specified for both single and three phase systems, 3 or 4 wire and are suitable for both balanced and unbalanced loads. The meters can be specified as a "display only" meter, or with a choice of one or two outputs. One relay or two relays that can be specified as latched or non latched, or an isolated analogue output with or without one relay output. Or with, or without RS485 MODBUS RTU which can also be with or without one relay output. The meter utilises the latest microprocessor technology in both the setting and operation of the meter.
MQ-5 (VAR)
For full specification Click Here
4½ Digit power meter with relay outputs, analogue signal output, RS485
Din 96x48mm digital single parameter power meters either as Watts, VAR or Power Factor. The meters can be specified for both single and three phase systems, 3 or 4 wire and are suitable for both balanced and unbalanced loads. The meters can be specified as a "display only" meter, or with a choice of one or two outputs. One relay or two relays that can be specified as latched or non latched, or an isolated analogue output with or without one relay output. Or with, or without RS485 MODBUS RTU which can also be with or without one relay output. The meter utilises the latest microprocessor technology in both the setting and operation of the meter.
MW-5 (WATT)
For full specification Click Here
DC Multi display power meter with relay outputs, analogue signal output, RS485
A Din 96x48mm multi display DC power meter. Measuring, displaying and communicating DC voltage, current, instantaneous power (Watts/KW), import and export Wh/KWh along with hours run. The voltage, current and power parameters also have max and min value recording during power on. The meter has the possibility for specifying up to 4 relay outputs including pulse outputs. The relays can be determined as set points for any of the parameters either low or high. In addition an analogue output also can be requested which can be assigned to any of the instantaneous measured parameters. Lastly, along with all the above mentioned outputs, RS485 MODBUS RTU communications can also be specified.
The VAW meter is particularly suitable for solar energy and wind energy systems, along with electroplating, battery and transport applications. A particular feature of this meter which is especially relevant in "green energy" applications, is that after a certain time of no operator interaction with the meter, the meter enters a "switch down" mode and reduces the power to the LEDs, thus saving money.