Foxtam AC current transducers can measure current either directly (max 7.5 Amps) or via the secondary of a current transformer, either 0-1 Amp or 0-5 Amp. The transducer converts the AC input current to an isolated analogue DC mA or DC voltage analogue signal output, directly proportional to the input. The 4KV isolated output signals can be utilised for many applications and can be fed into analogue meters, digital meters, PLC’s or BMS systems.
Foxtam AC voltage transducers can measure voltage either directly (max 600VAC) or via the secondary of a voltage transformer. The transducer converts the AC input voltage to an isolated analogue DC mA or DC voltage analogue signal output, directly proportional to the input. The 4KV isolated output signals can be utilised for many applications and can be fed into analogue meters, digital meters, PLC’s or BMS systems.
Foxtam active power (Watts) transducers can measure directly or via inputs from current transformers and/or voltage transformers. All active power transducers require a separate auxiliary supply. At the time of ordering the input details especially CT and VT input ratio details must be specified. Any specific scale range can also be determined, otherwise a sensible scale range from the input details supplied will be calculated. The 4KV isolated output signals are suitable for many applications, such as inputs to analogue and digital meters, PLC’s or BMS.
Foxtam combined active and reactive power (Watts & VAr) transducers can measure directly or via inputs from current transformers and/or voltage transformers. All combined active and reactive power transducers require a separate auxiliary supply. At the time of ordering the input details especially CT and VT input ratio details must be specified. Any specific scale range can also be determined, otherwise sensible scale ranges from the input details supplied will be calculated. The 4KV isolated output signals are suitable for many applications, such as inputs to analogue and digital meters, PLC’s or BMS systems.
Foxtam DC current transducers can measure DC current directly up to 10 Amps, above 10 Amps a shunt should be used in conjunction with a DC voltage transducer type FOX.TR.DU The transducer converts the input signal to either a DC mA or DC voltage analogue signal output, directly proportional to the input. All DC current transducer require an auxiliary supply voltage. The 4KV isolated output signals can be utilised for many applications and can be fed into analogue meters, digital meters, PLC’s or BMS systems.
Foxtam DC voltage transducers can measure DC voltages directly up to 600VDC, above 600VDC a voltage divider should be used. Specific 0-50mV, 60mV, 75mV are available for use directly with DC current shunts. The transducer converts the input signal to either a DC mA or DC voltage analogue signal output, directly proportional to the input. All DC voltage transducer require an auxiliary supply voltage. The 4KV isolated output signals can be utilised for many applications and can be fed into analogue meters, digital meters, PLC’s or BMS systems.
Foxtam frequency transducers measures “mains” frequency either directly or via a voltage transformer. The transducer converts the input signal to either a DC mA or DC voltage analogue signal output, directly proportional to the input. All frequency transducers are self powered and do not require a separate auxiliary supply. The 4KV isolated output signals can be utilised for many applications and can be fed into analogue meters, digital meters, PLC’s or BMS systems.
Foxtam power factor transducers measure the Cosine of the phase angle between the current and the voltage. All power factor transducers require a separate auxiliary supply. At the time of ordering the input voltage and current details especially any CT and VT input ratio details must be specified. Any specific power factor scale range can also be determined. The 4KV isolated output signals are suitable for many applications, such as inputs to analogue and digital meters, PLC’s or BMS systems and in particular power factor correction systems.
Foxtam reactive power (VAr) transducers can measure directly or via inputs from current transformers and/or voltage transformers. All reactive power transducers require a separate auxiliary supply. At the time of ordering the input details especially CT and VT input ratio details must be specified. Any specific scale range can also be determined, otherwise a sensible scale range from the input details supplied will be calculated. The 4KV isolated output signals are suitable for many applications, such as inputs to analogue and digital meters, PLC’s or BMS.