Accessories, For Y,8 & 11 series and YW,8W & 11W series timers and control relays. Panel mouting adaptors, Asymmetric Din adaptors, Screw terminal Sockects, Free sockets, Panel mounting accessories, Level probes,
A dedicated voltage, multi time range delay on break timer. Available as either din rail mounting or 8 anf 11 pin plug in. Time selection is achieved via 2 dip switches and by a percentage potentiometer. The timer is supplied on terminals A1 & A2 and the function is initiated trigger input to the �S1� terminal which energises the relay contacts, the timing commences immediately (leading edge). The contact will then time to de-energise.
An Attractive modern designed multi voltage, multi time range delay on break timer. A selector switch is provided to select one of eight different time ranges from 0.1 sec to 10 days, fine time selection on the selected range is achieved via a percentage potentiometer. The timer is supplied on terminals A1 & A2 and the function is initiated trigger input to the �S� terminal which energises the relay contacts, the timing commences after the trigger input is removed (trailing edge). The contact will then time to de-energise.
A dedicated voltage, multi time range delay on break timer. Available as either din rail mounting or 8 anf 11 pin plug in. Time selection is achieved via 2 dip switches and by a percentage potentiometer. The timer is supplied on terminals A1 & A2 and the function is initiated trigger input to the �S1� terminal which energises the relay contacts, the timing commences after the trigger input is removed (trailing edge). The contact will then time to de-energise.
A dedicated voltage, single time range delay on break timer. Available as either din rail mounting or 8 and 11 pin plug in. These timers are ideal for mass production OEM application, or for any application where operator interference must be kept to a minimum. Time selection is achieved via a percentage potentiometer. The timer is supplied on terminals A1 & A2 and the function is initiated trigger input to the �S1� terminal which energises the relay contacts, the timing commences after the trigger input is removed (trailing edge). The contact will then time to de-energise
Din rail or 8 and 11 pin plug in, series thyristor/triac output delay on timers. Operates on any supply from 20-260VAC/DC and is connected in series with the load. Available in a choice of three multi time ranges, a single time range or a fixed time setting.
A din rail mounted or 8 &11 pin plug in delay on make timer, with dedicated delay on timers. With duel coil voltage and a choice of 3 multi time range. The function is initiated by a supply on terminals A1 & A2 which commences the timing, the relay contacts will then energise after the timing period. removal of the supply after the timing period has been completed the relay contacts will de-energise.
Availible with either 8 or 11 pin plug in bases. With a dedicated coil supply and on a single adjustable time range. Delay on make timer with an instantaneous contact.
Din rail mounted or 8 & 11 pin plug in SPCO with a DPCO option on plug in units dedicated flasher relays, with dedicated coil voltages. The flashers are available as a standard fixed 1 sec On and 1 sec Off cycle ("DB" version) or with an adjustable cycle time, a set cycle time equates to "50% On & 50% Off". The relays can also on request, subject to a minimum quantity of 10 pieces, be factory set with any fixed cycle time, thus ensuring absolutely no operator interference. The timers feature a red LED to indicate relay output status. On connection of the supply voltage the relay contact/s immediately energise (pulse start) and remain energised for 50% of the cycle time, followed by a de-energisation for the next 50% of the cycle time. If the supply voltage is removed at any point, any remaining elapsed time is cancelled and if the relay contact/s are energised they will de-energise immediately
Din rail mounted or 8 & 11 pin plug in solid state output electronic flashers, available in either Triac output for AC circuits, or as a Transitor output for DC circuits. These devices are most suitable for applications where there is a prolonged flash rate and relay wear is of a concern. All terminal details with the CE mark is clearly marked on the sides of the housing. The AC Triac version is a "pause start" and of a fixed 1 sec cycle (0.5 sec Off & 0.5 sec On). The DC Transitor version is also a "pause start" and is available with a choice of adjustable cycle times. A set cycle time equates to 50% of the time as On and 50% of the time as Off. If the supply voltage is removed at any point, any remaining elapsed time is cancelled and if the output is On it will immediately switch to Off
Din rail or 8 and 11 pin plug in, series thyristor/triac output interval (delay off) timers. Operates on any supply from 20-260VAC/DC and is connected in series with the load. Available in a choice of three multi time ranges, a single time range or a fixed time setting.
Din rail mounted or 8 &11 pin plug in dedicated interval timer, with duel coil voltage(SPCO only), along with a choice of three multi time ranges.
A simple din rail mounted or 8 &11 pin plug in interval timer (delay to de-energise), with dedicated coil voltage and time range. These timers are ideal for mass production OEM application, or for any application where operator interference must be kept to a minimum.
Din rail mounted or 8 & 11 pin plug in SPCO and DPCO "mains restoration auto restart timers". The voltage and supply sensing built into these units are designed to sense voltage dips and momentary loss of supply referred to as "Brown Outs". This phenomena is a particular threat in the water industry and regularly occurs at remote pumping locations, especially during electrical storms. Left unchecked, a supply dip can "lock out" all or part of a control system, causing system malfunctions over a wide area necessitating engineers site visits, just to reset and restart a control system. By monitoring the supply these tried and proven Foxtam units will provide the "auto restart" signal to reset and restart the control system without the need for a site visit. For added convenience DPCO units are also available with the extra contact used as say a telemetry output to notify an operations centre that an incident has occurred. These timers are designed and operate in such a way that they reset as quick, if not quicker, than standard contactor and relay coils. They are offered in a choice of three functions: Delay on A function, Pulse H function and Delayed pulse Q function.
Din rail mounted or 8 & 11 pin plug in SPCO and DPCO "mains restoration auto restart timers". The voltage and supply sensing built into these units are designed to sense voltage dips and momentary loss of supply referred to as "Brown Outs". This phenomena is a particular threat in the water industry and regularly occurs at remote pumping locations, especially during electrical storms. Left unchecked, a supply dip can "lock out" all or part of a control system, causing system malfunctions over a wide area necessitating engineers site visits, just to reset and restart a control system. By monitoring the supply these tried and proven Foxtam units will provide the "auto restart" signal to reset and restart the control system without the need for a site visit. For added convenience DPCO units are also available with the extra contact used as say a telemetry output to notify an operations centre that an incident has occurred. These timers are designed and operate in such a way that they reset as quick, if not quicker, than standard contactor and relay coils. They are offered in a choice of three functions: Delay on A function, Pulse H function and Delayed pulse Q function. 1mSec version also available on request.
� Main Characteristics Mechanical time clocks, suitable for Din rail mounting, front panel mounting or surface mounting. When front panel mounted the front panel size is standard Din 72mm (panel cut out 68mm square). Available with or without 100 hour battery reserve either as a daily time clock or weekly time clock. On daily versions each setting peg equals 15 mins, on weekly versions each setting peg equals 2 hours. All versions feature captive time setting pegs, an override switch ON/OFF/AUTO and 16 Amp/250VAC rated switching contacts. The ALPHA clocks are stylish yet rugged and simple to use. A choice of 230VAC, 110VAC and 24VAC supply versions make them ideal for many applications.
An Attractive modern designed multi voltage, multi time range and multi function Din rail timer. Available with either SPCO or 4PCO. A selector switch is provided to select eight different time ranges from 0.1 sc to 10 days, fine time selection on the selected range is achieved via a percentage potentiometer. A further selector switch used to select one of eight different functions. FUNCTIONS:- Delay on (A). Interval (H). Delay off with trigger trailing edge (C). Single shot/Delay off with trigger leading edge (B). Delayed pulse (Q). Flasher pause first (D). Flasher pulse first (D/I). Latching (I).
� Description A Din standard 48mm front panel mounted electronic timer. The timer is multi time range. Selectable from the front are eight different time ranges from 1 sec - 600 hrs. The timer is also multi voltage 24 - 240VAC/DC. Fitted are two pairs of changeover contacts rated at 5Amps. The timer can be used for either delay on, or delay off applications, depending on what side the contacts are wired. A mode switch is also fitted (mode A or B). Mode A will facilitate two timed contacts and mode B one timed and one instant contact. Please note that the AH5R-G has now been superseded by the AH4CN-RG. This unit has the same functionality but comes in two voltage options 12-48VACDC and 100-240VACDC instead of specific voltages.
1 or 2 channels Daily and weekly program 30 memory locations ON, OFF or pulse functions (1 sec.) Holiday switching 1...99 days - (Permanently ON or OFF) Minimum interval 1 min. Switching capacity 16 A (per channel) Permanently ON or OFF with manual switch - (PERM ON/OFF) Manual override Analogue display of switching program for current day of the week (for each channel)
An attractive modern designed multi “everything” timer in a din rail mounted modular style housing of 1 module width (18mm). The timer features large double deck terminals suitable for up to 4mm2 cable. A selector switch is provided to select one of seven different time ranges from 0.1 sec to 100 hours, fine time selection on a selected range is then achieved via a percentage potentiometer. A further selector switch is then used to select one of ten different functions. A green supply on LED is featured along with a yellow LED to indicate relay output status. The green supply LED flashes to indicate timing.