Accessories, For Y,8 & 11 series and YW,8W & 11W series timers and control relays.
Panel mouting adaptors,
Asymmetric Din adaptors,
Screw terminal Sockects,
Free sockets,
Panel mounting accessories,
Level probes,
Accessories
For full specification Click Here
Asymmetrical cyclic relay output timers in either 8 or 11 pin plug in with a DPCO output version also as an 11 pin. Two selector switches are provided to select one of eight different time ranges from 1 sec to 100 days independently for both T1 & T2, fine time adjustment on a selected range is then achieved via the two percentage potentiometers. The time can be selected to be "pulse first" or "pause first" via an external wired link between pins 5 & 6. The timers feature a bi-colour LED to indicate output relay status, green when timing red when energised.
An attractive modern designed asymmetrical cyclic timer in a din rail mounted modular style housing.
The timer features the facility of double deck terminals thus enabling the timer to be available also in a unique 4PCO version. A selector switch is provided to select eight different time ranges from 1 sec to 100 days independently on both T1 & T2, fine time selection on a selected range is then achieved via the two percentage potentiometers. The timer can be selected to be "pulse first" via an external link fitted between terminals A1 and Y1, leaving the link open results in "pause first". A green supply on LED is featured along with a red LED to indicate relay output status.
Asymmetrical Recycling uni-d (spco) uni-4d (4pco)
For full specification Click Here
A dedicated voltage, single time range delay on break timer. Available as either din rail mounting or 8 and 11 pin plug in. These timers are ideal for mass production OEM application, or for any application where operator interference must be kept to a minimum. Time selection is achieved via a percentage potentiometer. The timer is supplied on terminals A1 & A2 and the function is initiated trigger input to the S1 terminal which energises the relay contacts, the timing commences immediately (leading edge). The contact will then time to de-energise.
delay off with trigger input.(leading edge). yrbf, 8rbf, 11rbf (spco) 11r2bf (dpco)
For full specification Click Here
A dedicated voltage, multi time range delay on break timer. Available as either din rail mounting or 8 anf 11 pin plug in. Time selection is achieved via 2 dip switches and by a percentage potentiometer. The timer is supplied on terminals A1 & A2 and the function is initiated trigger input to the S1 terminal which energises the relay contacts, the timing commences immediately (leading edge). The contact will then time to de-energise.
delay off with trigger input.(leadingedge). yrb, 8rb, 11rb (spco) 11r2b (dpco)
For full specification Click Here
An Attractive modern designed multi voltage, multi time range delay on break timer. A selector switch is provided to select one of eight different time ranges from 0.1 sec to 10 days, fine time selection on the selected range is achieved via a percentage potentiometer. The timer is supplied on terminals A1 & A2 and the function is initiated trigger input to the S terminal which energises the relay contacts, the timing commences after the trigger input is removed (trailing edge). The contact will then time to de-energise.
delay off with trigger input.(trailing edge) UNI-1C (SPCO) UNI-4C (4PCO)
For full specification Click Here
A dedicated voltage, multi time range delay on break timer. Available as either din rail mounting or 8 anf 11 pin plug in. Time selection is achieved via 2 dip switches and by a percentage potentiometer. The timer is supplied on terminals A1 & A2 and the function is initiated trigger input to the S1 terminal which energises the relay contacts, the timing commences after the trigger input is removed (trailing edge). The contact will then time to de-energise.
delay off with trigger input.(trailing edge). yrc, 8rc 11rc (spco) 11r2c (dpco)
For full specification Click Here
A dedicated voltage, single time range delay on break timer. Available as either din rail mounting or 8 and 11 pin plug in. These timers are ideal for mass production OEM application, or for any application where operator interference must be kept to a minimum. Time selection is achieved via a percentage potentiometer. The timer is supplied on terminals A1 & A2 and the function is initiated trigger input to the S1 terminal which energises the relay contacts, the timing commences after the trigger input is removed (trailing edge). The contact will then time to de-energise
delay off with trigger input.(trailing edge). yrcf, 8rcf, 11rcf (spco) 11r2cf (dpco)
For full specification Click Here
Din rail or 8 and 11 pin plug in, series thyristor/triac output delay on timers. Operates on any supply from 20-260VAC/DC and is connected in series with the load.
Available in a choice of three multi time ranges, a single time range or a fixed time setting.
delay on make series timer. YSA, 8SA, 11SA
For full specification Click Here
An Attractive modern designed multi voltage and multi time range dedicated delay on make timer. Available with either SPCO or 4PCO.
The function is initiated by a supply on terminals A1 & A2 which commences the timing, the relay contacts will then energise after the timing period. removal of the supply after the timing period has been completed the relay contacts will de-energise.
DELAY ON TIMER UNI-1A (SPCO) UNI-4A (4PCO)
For full specification Click Here
A din rail mounted or 8 &11 pin plug in delay on make timer, with dedicated delay on timers. With duel coil voltage and a choice of 3 multi time range.
The function is initiated by a supply on terminals A1 & A2 which commences the timing, the relay contacts will then energise after the timing period. removal of the supply after the timing period has been completed the relay contacts will de-energise.
DELAY ON TIMER. YRA, 8RA, 11RA (SPCO) 8R2A, 11R2A (DPCO)
For full specification Click Here
A simple din rail mounted or 8 &11 pin plug in delay on make timer, with dedicated coil voltage and time range. These timers are ideal for mass production OEM application, or for any application where operator interference must be kept to a minimum.
The function is initiated by a supply on terminals A1 & A2 which commences the timing, the relay contacts will then energise after the timing period. removal of the supply after the timing period has been completed the relay contacts will de-energise.
DELAY ON TIMER. YRAF, 8RAF, 11RAF (SPCO) 8R2AF, 11R2AF (DPCO)
For full specification Click Here
Availible with either 8 or 11 pin plug in bases. With a dedicated coil supply and on a single adjustable time range.
Delay on make timer with an instantaneous contact.
delay on with instantaneous contact. 8RAXF 11RAXF (1 X SPCO)
For full specification Click Here
An attractive modern designed duty changeover relay in a din rail mounted modular style housing of 1.5 modules width (27mm). A selector switch is provided to select one of four different fixed time ranges from 1 day to 1 month, (there is also a 10 second circuit proving setting). This is an ideal simple product to achieve a daily, weekly, fortnightly or monthly duty changeover on pumps, fans and similar equipment especially in the HVAC and pumping industry. A green supply on LED is featured along with a red LED to indicate relay output status.
duty change over relay uni-1b (spco) uni-4b (4pco )
For full specification Click Here
An 11 pin plug in engine start attempt relay for use in starting combustion engines connected to generators. The number of start attempts is selected by the middle selector switch 1-8. The start time is set by the top potentiometer between 3-30 sees and the recovery time by the bottom potentiometer between 6-60 sees. When the auxiliary supply (9-30VDC) is first applied (+2 & -10) the "Start" relay energises immediately for the "Start" time. After expiration of the "Start" time the relay de-energises for the "Recovery" time. This cycle continues for 1-8 times as set by the number on the "Attempts" switch. If the engine starts the power supply to terminals 2 & 10 should be thus wired so that it is interrupted. The "Alarm" relay will energise after the last start attempt thus an "engine fail to start alarm", this status will remain until the auxiliary supply is removed.
engine start relay 11r2es
For full specification Click Here
Din rail mounted or 8 & 11 pin plug in SPCO with a DPCO option on plug in units dedicated flasher relays, with dedicated coil voltages. The flashers are available as a standard fixed 1 sec On and 1 sec Off cycle ("DB" version) or with an adjustable cycle time, a set cycle time equates to "50% On & 50% Off". The relays can also on request, subject to a minimum quantity of 10 pieces, be factory set with any fixed cycle time, thus ensuring absolutely no operator interference. The timers feature a red LED to indicate relay output status.
On connection of the supply voltage the relay contact/s immediately energise (pulse start) and remain energised for 50% of the cycle time, followed by a de-energisation for the next 50% of the cycle time. If the supply voltage is removed at any point, any remaining elapsed time is cancelled and if the relay contact/s are energised they will de-energise immediately
Din rail mounted or 8 & 11 pin plug in solid state output electronic flashers, available in either Triac output for AC circuits, or as a Transitor output for DC circuits. These devices are most suitable for applications where there is a prolonged flash rate and relay wear is of a concern. All terminal details with the CE mark is clearly marked on the sides of the housing.
The AC Triac version is a "pause start" and of a fixed 1 sec cycle (0.5 sec Off & 0.5 sec On).
The DC Transitor version is also a "pause start" and is available with a choice of adjustable cycle times. A set cycle time equates to 50% of the time as On and 50% of the time as Off. If the supply voltage is removed at any point, any remaining elapsed time is cancelled and if the output is On it will immediately switch to Off
Simple din rail mounted or 8 and 11 pin plug in fleeting contact relay, available SPCO and with a DPCO option on 8 and 11 pin plug in units. The units have 4 selectable modes of operation changed via a dip switch on the top of the relay, the time of the fleeting contact is fixed at 0.5 sec. the 4 modes of operation are:-
1, Pulse on connection of supply.
2, Pulse on removal of the supply.
3, Pulse on both connection and removal of the coil supply.
4, Unit disabled.
Din rail or 8 and 11 pin plug in, series thyristor/triac output interval (delay off) timers. Operates on any supply from 20-260VAC/DC and is connected in series with the load.
Available in a choice of three multi time ranges, a single time range or a fixed time setting.
interval series timers. YSH 8SH 11SH
For full specification Click Here
Din rail mounted or 8 &11 pin plug in dedicated interval timer, with duel coil voltage(SPCO only), along with a choice of three multi time ranges.
A simple din rail mounted or 8 &11 pin plug in interval timer (delay to de-energise), with dedicated coil voltage and time range. These timers are ideal for mass production OEM application, or for any application where operator interference must be kept to a minimum.
Din rail mounted or 8 & 11 pin plug in SPCO and DPCO "mains restoration auto restart timers". The voltage and supply sensing built into these units are designed to sense voltage dips and momentary loss of supply referred to as "Brown Outs". This phenomena is a particular threat in the water industry and regularly occurs at remote pumping locations, especially during electrical storms. Left unchecked, a supply dip can "lock out" all or part of a control system, causing system malfunctions over a wide area necessitating engineers site visits, just to reset and restart a control system. By monitoring the supply these tried and proven Foxtam units will provide the "auto restart" signal to reset and restart the control system without the need for a site visit. For added convenience DPCO units are also available with the extra contact used as say a telemetry output to notify an operations centre that an incident has occurred.
These timers are designed and operate in such a way that they reset as quick, if not quicker, than standard contactor and relay coils. They are offered in a choice of three functions: Delay on A function, Pulse H function and Delayed pulse Q function.
Din rail mounted or 8 & 11 pin plug in SPCO and DPCO "mains restoration auto restart timers". The voltage and supply sensing built into these units are designed to sense voltage dips and momentary loss of supply referred to as "Brown Outs". This phenomena is a particular threat in the water industry and regularly occurs at remote pumping locations, especially during electrical storms. Left unchecked, a supply dip can "lock out" all or part of a control system, causing system malfunctions over a wide area necessitating engineers site visits, just to reset and restart a control system. By monitoring the supply these tried and proven Foxtam units will provide the "auto restart" signal to reset and restart the control system without the need for a site visit. For added convenience DPCO units are also available with the extra contact used as say a telemetry output to notify an operations centre that an incident has occurred.
These timers are designed and operate in such a way that they reset as quick, if not quicker, than standard contactor and relay coils. They are offered in a choice of three functions: Delay on A function, Pulse H function and Delayed pulse Q function.
Mechanical extension timers, totally mechanically driven by clockwork spring, no auxiliary supply voltage required. The moment the setting knob is turned past zero to the set time required, the contacts switch, the timer will then start running back to zero. When zero is reached the contacts will switch back.
If after the initial time has been set, it is required that the set time needs to be lengthened or shortened, this can be done by turning the knob to the new time required without harming the mechanical mechanism. The timer benefits from 15Amp or 16Amp contacts (dependant on type) and is easily fitted to the front of a control panel via screw fixings.
Mechanical Extension Timers
For full specification Click Here
Main Characteristics
Mechanical time clocks, suitable for Din rail mounting, front panel mounting or surface mounting. When front panel mounted the front panel size is standard Din 72mm (panel cut out 68mm square). Available with or without 100 hour battery reserve either as a daily time clock or weekly time clock. On daily versions each setting peg equals 15 mins, on weekly versions each setting peg equals 2 hours. All versions feature captive time setting pegs, an override switch ON/OFF/AUTO and 16 Amp/250VAC rated switching contacts.
The ALPHA clocks are stylish yet rugged and simple to use. A choice of 230VAC, 110VAC and 24VAC supply versions make them ideal for many applications.
Mechanical Time Clocks
For full specification Click Here
An Attractive modern designed multi voltage, multi time range and multi function Din rail timer. Available with either SPCO or 4PCO.
A selector switch is provided to select eight different time ranges from 0.1 sc to 10 days, fine time selection on the selected range is achieved via a percentage potentiometer. A further selector switch used to select one of eight different functions.
FUNCTIONS:-
Delay on (A). Interval (H).
Delay off with trigger trailing edge (C). Single shot/Delay off with trigger leading edge (B).
Delayed pulse (Q). Flasher pause first (D).
Flasher pulse first (D/I). Latching (I).
MULTI TIMERS UNI-1M (SPCO) UNI-4M (4PCO)
For full specification Click Here
An Attractive designed multi voltage, multi time range and multi function. Plug in timer. Available with either SPCO or DPCO.
A selector switch is provided to select eight different time ranges from 0.1 sc to 10 days, fine time selection on the selected range is achieved via a percentage potentiometer. A further selector switch used to select one of eight different functions.
FUNCTIONS:
Delay on (A). Interval (H).
Delay off with trigger trailing edge (C). Single shot/Delay off with trigger leading edge (B).
Delayed pulse (Q). Flasher pause first (D).
Flasher pulse first (D/I). Latching.
MULTI TIMERS UNI-81M, UNI-11-1M (SPCO). UNI-11-2M (DPCO)
For full specification Click Here
Description
A Din standard 48mm front panel mounted electronic timer. The timer is multi time range. Selectable from the front are eight different time ranges from 1 sec - 600 hrs.
The timer is also multi voltage 24 - 240VAC/DC. Fitted are two pairs of changeover contacts rated at 5Amps. The timer can be used for either delay on, or delay off applications, depending on what side the contacts are wired.
A mode switch is also fitted (mode A or B). Mode A will facilitate two timed contacts and mode B one timed and one instant contact.
Please note that the AH5R-G has now been superseded by the AH4CN-RG. This unit has the same functionality but comes in two voltage options 12-48VACDC and 100-240VACDC instead of specific voltages.
Panel Mounted Timers - 48mm
For full specification Click Here
Miniature electronic 4 pole timer with multiple time ranges and multiple functions. Two front mounted LEDs show the presence of power feed and relay status.
plug in 4PCO Timers
For full specification Click Here
1 or 2 channels
Daily and weekly program
30 memory locations
ON, OFF or pulse functions (1 sec.)
Holiday switching 1...99 days - (Permanently ON or OFF)
Minimum interval 1 min.
Switching capacity 16 A (per channel)
Permanently ON or OFF with manual switch - (PERM ON/OFF)
Manual override
Analogue display of switching program for current day of the week (for each channel)
Programmable Time Switch
For full specification Click Here
An Attractive modern designed multi voltage, multi time range star delta timer. A selector switch is provided to select four different star time ranges from 0.1 sc to 10 mins, fine time selection on the selected range is achieved via a percentage potentiometer. On connection of the supply voltage the "Star" contact remains closed and timing immediately commences, after the expiry of the set delay time the "Star" contact opens. There then follows a dwell time of 100mSec (on request 30mSec) and the separate "Delta" contact then closes
star delta. uni-2q (2 x spco) uni-4q (2 x dpco)
For full specification Click Here
Din rail mounted or 8 & 11 pin plug in star delta timers, dedicated coil voltage and dedicated adjustable time range. The timers have two independent contact outputs, one designed as Star and one as Delta. The timers are with a single adjustable time range and feature a red LED to indicate completion of the "Star" time. On connection of the supply voltage the "Star" contact remains closed and timing immediately commences, after the expiry of the set delay time the "Star" contact opens. There then follows a dwell time of 100mSec (on request 30mSec) and the separate "Delta" contact then closes
star delta. yr2q 8r2q 11r2q
For full specification Click Here
An Attractive modern designed true delay off timer. Multi voltage, multi time range up to 30 MINS!
The units supply voltage is selectable by an input to 1 of 3 different terminals.
The relay(s) will energise immediately the supply voltage is applied. When the supply voltage is removed the relay is held energised until the timing period has elapsed and the relay(s) will de-energise.
true delay on break. multi voltage multi time range. UNI-1K (spco) UNI-2K (dpco)
For full specification Click Here
A simple true delay off timer. Single voltage, single adjustable time range. Up to 20 mins.
These timers are ideal for mass production OEM application, or for any application where operator interference must be kept to a minimum.
The relay(s) will energise immediately the supply voltage is applied. When the supply voltage is removed the relay is held energised until the timing period has elapsed and the relay(s) will de-energise.
true delay on break. yrk.f 8rk.f 11rk.f (spco) 8r2k.f 11r2k.f(dpco)
For full specification Click Here
A din rail mounted or 8 &11 pin plug true delay off timer. Single voltage and Multi time range.
The relay(s) will energise immediately the supply voltage is applied. When the supply voltage is removed the relay is held energised until the timing period has elapsed and the relay(s) will de-energise.
true delay on break. yrk.m 8rk.m 11rk.m (spco) 8r2k.m 11r2k.m(dpco)